ProTek® Blast Mitigation Products Overview

Arena/Open Air Test

  • ASTM F1642
  • GSA-TS01-2003
  • 6 PSI/41 PSI* MSC
  • GSA Performance: Minimum 3B
  • Contact YKK AP for Glazing Options

Storefront

YKK AP YHS 50 TUH

  • 5’-0” x 8’-0” & 5’-0” x 2’-0” Lites of Glass
  • Thermally Broken
  • Dry Glaze Option for Blast Mitigation
  • Wet Glazed for Blast & Hurricane Applications

Curtain Wall

YKK AP YHC 300 OG (Outside Glazed)

  • 20’ x 26’ Wall Tested
  • Intermediate Anchors
  • Vertical Splice
  • 5’-0” x 8’-0” & 5’-0” x 2’-0” Lites of Glass
  • Thermally Improved
  • Dry Glaze Option for Blast Mitigation
  • Wet Glazed for Blast & Hurricane Applications

Entrance Doors

YKK AP 35H Swing Door

  • Pairs up to 7’-0” x 8’-0”
  • Maximum Security Lock
  • Exit Device
  • Dry Glaze Option for Blast Mitigation
  • Wet Glazed for Blast & Hurricane Applications

Fixed & Operable Windows

proteck_impact_resistant_windows

YKK AP YOW 225 TUH

  • Outswing Casement
  • Project Out Vents
  • Fixed Lites
  • Thermally Broken
  • Wet Glazed Only

proteck_impact_resistant_windows_2

 

YKK AP YVS 410 TUH

  • Single Hung
  • Thermally Broken
  • Wet Glazed Only

 

 

System & Glass Type
(Monolithic or Insulating)
DoD UFC 4-010-05 StandardGSA TS01-03 StandardAAMA 510-06 StandardEngineering CalculationsTest per ASTM F1642 @ 6psi, 41psi* msc**Dry Glazed Option**
35H Monolithic
YHS 50 Monolithic   
YHS 50FI Insulating  
YHS 50TU Insulating
YHC 300OG Monolithic   
YHC 300OG Insulating
YHC 300SSG Monolithic   
YHC 300SSG Insulating  
YHC 300IG Monolithic   
YHC 300 IG Insulating  
YOW 225H Monolithic   
YOW 225TUH Insulating 
YVS 410TUH Insulating 
**Optional Testing by YKK AP for Enhanced Performance